1. Electric Specification:
CE No.(RC-100-12/24) Model: | RC-60W-12V | RC-60W-24V | ||
Output | DC current | 12V | 24V | |
Rated Current | 5A | 2.5A | ||
Current Range | 0-5A | 0-2.5A | ||
Rated Power | 60W | 60W | ||
Ripple&Noise Max. | 120MV VPP | 200MV VPP | ||
Voltage arrangement range | 10.8-13.2V | 21.6-26.4V | ||
Voltage Accuracy | ±2﹪ | ±2﹪ | ||
Linear adjustment rate | ±0.5﹪ | ±0.5﹪ | ||
Load adjustment rate | ±0.5﹪ | ±0.5﹪ | ||
Rise, start-up time | 500MS.30MS/230VAC 1200MS.30MS/115VAC full load | |||
Hold up time(TYP) | 20MS/230VAC 10MS/115VAC full load | |||
Input | Voltage range | 100V-264V or 120-370VDC | ||
Frequency range | 47-63HZ | |||
Efficiency | 82% | 84% | ||
AC Current | 1A/115VAC 0.6A/230VAC | |||
Inrushed Current | 45A Cold Start | |||
Leakage Current | <2.5MA/240VAC | |||
Protection | Overload | 110%-150% rated output power | ||
Short Circuit | Protection mode,closed output, auto-recovery after removal of power supply abnormal conditions | |||
Environment
| Working temperature | -20-60℃ (please refer to the load derating curve) | ||
Working humidity | 20-90%. non-condensing | |||
Storage temperature/humidity | -40-85℃.10-95% | |||
temperature coefficient | ±0.03%/℃(0-45℃) | |||
Vibration resistance | 10-500HZ.2G 10 min/cycle. X.Y.Z Axis 60 min each | |||
Safety Standards and Electromagnetic Compatibility
| Safety standard | IEC 60950-1 | ||
withstand voltage | I/P-O/P:1500VAV I/P-FG:1000VAC O/P-FG:500VAC | |||
Insulation resistance | I/P-O/P. I/P-FG. O/P-FG 50M/500VAC | |||
Electromagnetic interference | Refer to EN55015:2006+A1:2007+A2:2009 | |||
Harmonic currents | Refer to EN61000-3-2:2006+A1:2009+A2:2009 | |||
Withstand electromagnetic | Refer to EN61000-4-8 | |||
Others | Size: 146*91.3*47mm | |||
Package:0.48KG 40PCS/ box 19KG | ||||
Supplement: | 1. If not specified, all specification parameter input is 230VAC rated load. Test under 25℃ environment. 2. Ripple&Noise testing methods: use a No.12 double twisted strand, and connect the terminal with 0.1 UF and 0.47UF electronic capacitors at the same time. Test under 20MHZ bandwidth. 3. Accuracy: including deviation, linear adjustment rate and load adjustment rate. 4. Linear adjustment rate testing method: from low voltage to high voltage under rated load. 5. Load adjustment rate testing method: from 0 to 100% rated load. 6. The power supply should be considered as a part of the components in the system. It should be combined with the terminal to process confirmation of electromagnetic compatibility. |
You May Like
- Free Member
- Trade Assurance
Business Type : Manufacturer
Company Location: GUANG DONG
Year Established: 31YRS
You May Like
-
RC-36W-24V LED Constant Voltage power supply parameter
-
RC-36W-12V LED Constant Voltage power supply parameter
-
RC-24W-24V LED Constant Voltage power supply parameter
-
RC-24W-12V LED Constant Voltage power supply parameter
-
RC-48W-12V LED Constant Voltage power supply parameter
-
RC-48W-24V LED Constant Voltage power supply parameter
-
RC-60W-12V LED Constant Voltage power supply parameter
-
RC-96W-12V LED Constant Voltage power supply parameter
-
RC-96W-24V LED Constant Voltage power supply parameter
-
RC-120W-12V LED Constant Voltage power supply parameter