Welcome to Iightstrade.com!

RC-36W-24VP LED Constant Voltage power supply parameter

MOQ :40 piece

Lead Time :10 Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : Western Union

Departure Port : shenzhen

Product details

Supply Ability

  • Supply Ability:10000 piecesWarranty(Year):1 Year

Product Specifications

  • Brand name:R&C

Product Description

1. Electric Specification

CE No.RC-50-12/24        Model

RC-36W-12V

RC-36W-24V

 

 

 

 

Output

DC current

12V

24V

Rated Current

3A

1.5A

Current Range

0-3A

0-1.5A

Rated Power

36W

36W

Ripple&Noise Max.

120MV VPP

200MV VPP

Voltage arrangement range

10.8-13.2V

21.6-26.4V

Voltage Accuracy

±2

±2

Linear adjustment rate

±0.5

±0.5

Load adjustment rate

±0.5

±0.5

Rise, start-up time

500MS.30MS/230VAC 1200MS.30MS/115VAC full load

Hold up timeTYP

20MS/230VAC  10MS/115VAC full load

 

 

Input

Voltage range

100V-264V or 120-370VDC

Frequency range

47-63HZ

Efficiency

82%

84%

AC Current

1A/115VAC  0.6A/230VAC

Inrushed Current

45A Cold Start

Leakage Current

2.5MA/240VAC

Protection

Overload

110%-150% rated output power

Short Circuit

Protection modeclosed output, auto-recovery after removal of power supply abnormal conditions

 

 

Environment

 

Working temperature

-20-60℃(please refer to the load derating curve)

Working humidity

20-90%. non-condensing

Storage temperature/humidity

-40-85℃.10-95%

temperature coefficient

±0.03%/℃(0-45℃)

Vibration resistance

10-500HZ.2G 10 min/cycle. X.Y.Z Axis 60 min each

 

 

Safety Standards and Electromagnetic Compatibility

 

Safety standard

IEC 60950-1 

withstand voltage

I/P-O/P:1500VAV  I/P-FG:1000VAC  O/P-FG:500VAC

Insulation resistance

I/P-O/P.  I/P-FG.  O/P-FG   50M/500VAC

Electromagnetic interference

Refer to EN550152006+A12007+A2:2009

Harmonic currents

Refer to EN61000-3-22006+A12009+A22009

Withstand electromagnetic

Refer to EN61000-4-8

Others

Size: 146*91.3*47mm

Package0.48KG  40PCS/box  19KG

Supplement

1.      If not specified, all specification parameter input is 230VAC rated load. Test under

25℃ environment.

2.      Ripple&Noise testing methods: use a No.12 double twisted strand, and connect the terminal with 0.1 UF and 0.47UF electronic capacitors at the same time. Test under 20MHZ bandwidth.

3.      Accuracy: including deviation, linear adjustment rate and load adjustment rate.

4.      Linear adjustment rate testing method: from low voltage to high voltage under rated load.

5.      Load adjustment rate testing method: from 0 to 100% rated load.

6.  The power supply should be considered as a part of the components in the system. It should be combined with the terminal to process confirmation of electromagnetic compatibility.